The Rosemount 6888A In Situ Oxygen Analyzer helps optimize any industrial or large commercial boiler, fired heater or kiln by analyzing the oxygen within the flue gas. As part of an oxygen trim system, the Rosemount 6888A analyzer helps improve plant efficiency and lower energy costs. It's simple to install, commission and operate. The sensor, diffusers, and accessories were developed to provide the greatest performance and longevity even in the harshest of process conditions.
Response Time: Up to 8 sec T90
Process Temperature Range: Up to 1300 °F (705 °C) or 1922 °F (1050 °C) with optional bypass and jacket
Ambient Temperature: -40 to 158 °F (-40 to 70 °C)
Dimensions: Probe Length Options from 18 in (0.46 m) to 12 ft (3.66 m)
Communication Protocol: 4-20 mA HART, FOUNDATION Fieldbus
Certifications/Approvals: Hazardous location, see full specs for complete list of certifications
Measurement Type: Oxygen, Zirconia - Brazed Disk
Accuracy: ±0.75% of reading or ±0.05% O2, whichever is greater
Measurement Range: 0 to 10% or 0 to 50%