Pipe Clamp Materials: ASTM 304 SST (1.4301), Duplex F51 (1.4462), Carbon steel (1.0037)
Lead Wires: PTFE insulated, silver-coated copper wire
Insulation Resistance: 1,000 MΩ minimum insulation resistance when measured at 500 V dc at room temperature
Calibration Options: Class A Sensor from -50 to 300 °C (-58 to 572 °F)
Certifications/Approvals: Hazardous location, see full specs for complete list of certifications
Input: Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal: 4-20 mA /HART® protocol
Housing: DIN rail mount
Diagnostics: Basic diagnostics including open/short sensor diagnostics
Calibration Options: 5-point calibration
Certifications/Approvals: Hazardous location, marine type, RoHS Compliant (Directive 2002/95/EC). See full specs for complete list of certifications