Flow Rate: Up to 504 kg/hr (1110 lb/hr)
Liquid Mass Flow Acccuracy: Up to±0.1% of rate
Liquid Mass Flow Repeatability: Up to±0.05% of rate
Gas Mass Flow Accuracy: ±0.5% of rate
Gas Mass Flow Repeatability: ±0.25% of rate
Liquid Density Accuracy: up to ± 0.001 g/cc at standard conditions
Fluid temperature Range: -46 C to 200 C (-50 - 392 F)
Pressure Range: 0-13,960 psi (0-963 bar)
Available Outputs: Model 1500 : for applications requiring one flow rate variable ( in milliamp and a frequency/pulse outputModel 2500 : for applications requiring simultaneous monitoring of multiple flow variables in combinations of outputs (mill
Housing: Polyamide PA 6.6
Power: • Minimum 19.2 to28.8 VDC• 6.3 watts• Meets Installation (Overvoltage) Category II, Pollution Degree 2 requirements
Input/output signals: • One active 4–20 mA output• One active frequency output
HART: Bell 202 signal is superimposed on the primary milliamp output
Mounting options: Remote-mount control room only• Mounted on 35 mm rail• Rail must be grounded
Application types: • Continuous process control• Two-phase flow/entrained gas• Filling &dosing• Meter verification
Hazardous approvals: Suitable for non-hazardous environments only