Mass flow accuracy (Liquid): ±0.20% of rate (standard)±0.10% of rate (optional)
Mass flow repeatability (Liquid): ±0.10% of rate (standard)±0.05% of rate (optional)
Volume flow accuracy (Liquid): ±0.20% of rate (standard)±0.15% of rate (optional)±0.10% of rate (optional)
Volume flow repeatability (Liquid): ±0.14% of rate (standard)±0.075% of rate (optional)
Mass flow accuracy (Gas): ±0.5% of rate
Mass flow repeatability (Gas): ±0.25% of rate
Density accuracy (Liquid): ±0.002 g/cm³ (2.0 kg/m³)
Temperature accuracy: ±1 °C ±0.5% of reading
Sensor maximum working pressure: 6,250 psig (431 barg)
Meter approvals, calibrations, and certifications: •CSA•IECEx•ATEX•Marine (U.S., U.K., Norway-Germany, France, and Japan)•Ingress Protection•EMC effects
Output variables: Mass flowVolume flow
Local display: Standard user interface with 2-line LCD panelTwo optical switches for local operationGlass or plastic lens options
Power: Self-switching AC/DC input, automatically recognizes supply voltage85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum18 to 100 VDC, 6 watts typical, 11 watts maximumComplies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
Input/output signals: One active 4–20 mA outputOne active frequencty outputFrequency output can be configured as a discrete output
HART: Bell 202 signal is superimposed on the primary milliamp output
Mounting options: Field-mountIntegrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensorRemotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types: Continuous process controlTwo-phase flow/entrained gasMeter verificationSIS Certified
Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2