The Flexim FLUXUS G532 Compressed Air Ultrasonic Flow Meter is specially designed for quantity measurement of compressed air and technical gases. A compact compressed air meter with integrated standard volume flow calculation, which can also process online measurement data from temperature and pressure sensors. The proven transit time difference method offers great advantages, especially for compressed air and technical gases, such as: Flow velocities as low as 0.03 ft/s are detected, the measurement is always bi-directional and is not influenced by moisture, oil or dirt particles. FLUXUS G532 CA has a USB and LAN interface and operates the common communication interfaces Modbus TCP, Modbus RTU, BACnet MS/TP, BACnet IP and M-Bus.
Fluid Type: Compressed air, industrial, pharmaceutical and clean gases
Accuracy: Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 of reading ±0.005 m/s ( ±0.02 ft/s)Measurement uncertainty at the measuring point (volumetric flow rate):: ±1 to 2% of reading ±0.005 m/s (±0.02 ft/s)
Repeatability: 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
Flow channels: 1
Range: Flow Velocity Range: 0.01...35 m/s (0.03 to 115 ft/s) , depending on the pipe diameter
Certifications/approvals: Ordloc (FM)
Power supply: 90 to 250 VAC / 50 to 60 Hz11 to 32 VDC
Pipe size: 7…360mm (0,28…14,2 inch)
Pressure range: 1 barg (15 psig)...Unlimited
Temperature range (media): -40 to +130°C (-40 to 266 °F)
Output: 4-20mA active/passive according to NAMUR NE43pulse/frequency/binary
Input: Temperature4..20mA
Communication protocol: Modbus RTUBACnet MS/TPHART®Modbus TCPM-BusBACnet IPUSBLAN
System configuration and installation: For more detailed Information please download the Technical Specifications