The FLUXUS SIL F ADM8X27 non-intrusive ultrasonic flow meters are SIL-rated, functional safety approved. As the wetted parts of inline measuring devices are not subject to the Failure Mode Effects and Diagnostics Analysis (FMEDA), they are not included in the scope of certification - presenting a safety risk. The SIL 2 certification of the FLUXUS non-intrusive flow meter includes the entire measuring system -the measuring transmitters and transducers. It also includes the patented WaveInjector mounting fixture for extreme temperatures, allowing the non-intrusive flow measurement at liquid temperatures from as low as -275 °F up to +1100 °F. Flexim also offers special radiation-resistant transducers for use in the nuclear industry.
Fluid Type: All liquids
Accuracy: Measurement uncertainty at the measuring point (volumetric flow rate): ± 0.5…1.6 % of reading ±0,005 m/s (±0.02 ft/s)
Repeatability: 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
Flow channels: up to 2
Range: Flow Velocity Range: 0,01 to 25 m/s (0.03 to 82 ft/s), depending on pipe diameter
Certifications/Approvals: ATEX/IECEx Zone 1
Power supply: 100-230VAC20-32VDC
Pipe size: 6 to 6500 mm (0.24 to 255.9 inch)
Pressure range: -
Temperature range (media): -40 to +200°C (-40 to +390°F) / WI: -200 to +630°C (-328 to +1166 °F)
Output: 4-20mA active/passivebinary
Input: -
Communication Protocol: RS232
System configuration and installation: For more detailed Information please download the Technical Specifications