A dual-compartment transmitter housing provides isolation from the external environment. Advanced diagnostics and through-the-glass Local Operator Interface offer unparalleled process insight.
Sensor compatibility: Compatible with Rosemount 8705, 8711, and 8721sensors. Compatible with AC and DC powered sensors ofother manufacturers.
Transmitter coil drive current: 500mA
Flow rate range: Capable of processing signals from fluids that are travelingbetween 0.04 and 39 ft/s (0.01 to 12 m/s) for both forwardand reverse flow in all sensor sizes. Full scale continuouslyadjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity limits: Process liquid must have a conductivity of5 microSiemens/cm (5 micromhos/cm) or greater.
Power supply: 90 - 250VAC, 50/60Hz or 12 - 42VDC
Line power fuses: 90-250VAC systems1A, 250V, I2t, 1.5 A2s Rating, Fast ActingBussman AGC-1, Littlefuse 31201.5HXP12-42VDC systems3 Amp, 250V, I2t, 14 A2s Rating, Fast ActingBel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135
Line power fuses: 15W maximum - DC40VA maximum - AC
Switch-on current: AC: Maximum 35.7A (< 5ms) at 250VACDC: Maximum 42A (< 5ms) at 42VDC