close
close

Rosemount

Micro Motion R-Series Coriolis Meter Consisting of R025P Sensor and 2700 Transmitter

Write a Review
SKU:
micro-motion-pkg-ft-r025p-2700
Request a Quote
Mass flow accuracy (Liquid): ±0.50% of rate (standard)±0.40% of rate (optional) Mass flow repeatability (Liquid): ±0.25% of rate (standard)±0.20% of rate (optional) Volume flow accuracy (Liquid): ±0.50% of rate Volume flow repeatability (Liquid): ±0.25% of rate Mass flow accuracy (Gas): ±0.75% of rate Mass flow repeatability (Gas): ±0.50% of rate Density accuracy (Liquid): ±0.01 g/cm³ (10.0 kg/m³) (standard)±0.003 g/cm³ (3.0 kg/m³) (optional) Temperature accuracy: ±1 °C ±0.5% of reading Sensor maximum working pressure: 2,300 psig (159 barg) Meter approvals, calibrations, and certifications: • CSA• IECEx• NEPSI• ATEX Output variables: Mass & volume flowNet product content / flowTemperatureDensityConcentration Local display: Standard user interface with 2-line LCD panelTwo optical switches for local operationGlass or plastic lens options Power: Self-switching AC/DC input, automatically recognizes supply voltage85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum18 to 100 VDC, 6 watts typical, 11 watts maximumComplies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2 Input/output signals: Not intrinsically safeAnalog output option:One active 4–20 mA outputOne active frequencty outputFrequency output can be configured as a discrete outputConfigurable I/O option:One or two active 4-20 mA outputsOne or two active/passive frequency outputsOne or two active/passive discrete outputsOne discrete inputIntrinsically safeAnalog output option:One passive 4-20 mA outputOne passive frequency outputFrequency output can be configured as a discrete outputFoundation™ fieldbus (Obsolete)optionally non-incendiveOne Foundation fieldbus H1 outputPROFIBUS-PA (Obsolete)One PROFIBUS-PA output HART/WirelessHART: Bell 202 signal is superimposed on the primary milliamp outputWirelessHART available via THUM adapterHART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions Mounting options: Field-mountIntegrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensorRemotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor Application types: Continuous process controlCustody transferTwo-phase flow/entrained gasMeter verificationSIS Certified Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2 HART/WirelessHART: Bell 202 signal is superimposed on the primary milliamp outputWirelessHART available via THUM adapterHART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions Mounting options: Field-mount•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor Application types: Continuous process controlCustody transferTwo-phase flow/entrained gasMeter verificationSIS Certified Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2
Worldwide Shipping
Tailored Quotation
Secure Shopping
24/7 Customer Support
Icon Hot
Icon Hot