Flow Rate: Up to 504 kg/hr (1110 lb/hr)
Liquid Mass Flow Acccuracy: Up to±0.1% of rate
Liquid Mass Flow Repeatability: Up to±0.05% of rate
Gas Mass Flow Accuracy: ±0.5% of rate
Gas Mass Flow Repeatability: ±0.25% of rate
Liquid Density Accuracy: up to ± 0.001 g/cc at standard conditions
Fluid temperature Range: -46 C to 200 C (-50 - 392 F)
Pressure Range: 0-6991 psi (0-482 bar)
Output variables: Mass flowVolume flow
Local display: Standard user interface with 2-line LCD panelTwo optical switches for local operationGlass or plastic lens options
Power: Self-switching AC/DC input, automatically recognizes supply voltage85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum18 to 100 VDC, 6 watts typical, 11 watts maximumComplies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
Input/output signals: One active 4–20 mA outputOne active frequencty outputFrequency output can be configured as a discrete output
HART: Bell 202 signal is superimposed on the primary milliamp output
Mounting options: Field-mountIntegrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensorRemotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types: Continuous process controlTwo-phase flow/entrained gasMeter verificationSIS Certified
Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2