Mass flow accuracy (Liquid): ±0.15% of rate (standard)±0.10% of rate (optional)
Mass flow repeatability (Liquid): ±0.05% of rate
Volume flow accuracy (Liquid): ±0.25% of rate (standard)±0.15% of rate (optional)
Volume flow repeatability (Liquid): ±0.05% of rate
Mass flow accuracy (Gas): ±0.50% of rate
Mass flow repeatability (Gas): ±0.25% of rate
Density accuracy (Liquid): ±0.002 g/cm3 (±2.0 kg/m3) (standard)±0.001 g/cm3 (±1.0 kg/m3) (optional)
Temperature accuracy: ±1 °C ±0.5% of reading
Sensor maximum working pressure: 1,015 psig (70 barg)
Meter approvals, calibrations, and certifications: •CSA•IECEx•ATEX
Local display: Graphical backlit displayFour-button optical controlsFlowmeter-status LEDSupports English, German, French, Spanish, Portuguese, Russian, Chinese, and Japanese languages.
Power: Self-switching AC/DC input, automatically recognizes supply voltage85 to 2405 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum18 to 100 VDC, 6 watts typical, 11 watts maximumComplies with Low Voltage Directive 2006/95/EC per IEC 61010-1 Ed. 3.0 2010-06; Overvoltage Category II, Pollution Degree 2
Universal Service Port: Universal Service Port design allows for connection and data transfer using standard, readily available equipment.
Configurable I/O version: Up to 5 licensable channels with the following possible configurations:1 to 3 4-20 mA outputs1 to 3 Pulse outputs1 to 3 Discrete outputs1 to 2 Discrete inputs1 mA input1 Modbus/RS-485Channel A: mA/HARTChannel B: mA/FO/DOChannel C: mA/FO/DO/DIChannel D: mA-input/FO/DO/DIChannel E: Modbus RS-485
Communication Protocol: WirelessHARTWirelessHART available with the 775 Smart Wireless THUM adapter.FOUNDATION Fieldbus versionFOUNDATION Fieldbus channelmA outputPulse outputPROFIBUS-PA versionPROFIBUS-PA channelmA IS outputPulse IS output
Wi-Fi Display Option:: Wi-Fi display option enables point-to-point wireless communication in order to configure and characterize the meter, download historical files, and run Smart Meter Verification for troubleshooting purposes. Available for the 5700 Config I/O version only.
Intrinsically Safe version: Up to 4 licensable IS channels with the following configurations:Channel A: mA/HARTChannel B: mAChannel C: mA/FOChannel D: FOChannel E: Not UsedSIL Certified Device Available – Uses an internal readback loop to verify the milliamp output
Ethernet version: Dual Ethernet ports supporting EtherNet/IP, Modbus TCP, and PROFINET all in one deviceAdditional channel included configurable to mA output, pulse output, discrete output, or discrete inputPre-installed M12 quick connections available as an option
Mounting options: Field-mount aluminum and stainless steel housing optionsIntegrally mounted to a Micro Motion ELITE (CMFS), F-series, H-series, R-series, or T-series Coriolis sensor (aluminum only)Remotely mounted to any 4-wire or 9-wire Micro Motion ELITE®, F-series, H-series, R-series, or T-series Coriolis sensor (aluminum and stainless steel versions)
Application types: Smart Meter Verification ProfessionalDiscrete batch controlPetroleum measurement and API correction optionConcentration measurementAdvanced Phase Measurement for two phase flow remediationPiecewise Linearization for Gas Applications
Certificates/Approvals: Hazardous approvalsClass I, Div. 1Class I, Div. 2Zone 1Zone 2SIL/SIS Certification5700 Config I/O and Intrinsically Safe versions are certified for SIL2 single use and SIL3 multiple use safety applications per IEC 61508. Please refer to the Safety Manual in the document manuals and guides section.