Mass flow accuracy (Liquid): ±0.20% of rate (standard)±0.15% of rate (optional)±0.10% of rate (optional)
Mass flow repeatability (Liquid): ±0.050% of rate
Volume flow accuracy (Liquid): ±0.20% of rate (standard)±0.15% of rate (optional)±0.10% of rate (optional)
Volume flow repeatability (Liquid): ±0.050% of rate
Mass flow accuracy (Gas): ±0.5% of rate
Mass flow repeatability (Gas): ±0.25% of rate
Density accuracy (Liquid): ±0.002 g/cm³ (2.0 kg/m³) (standard)±0.001 g/cm³ (1.0 kg/m³) (optional)
Temperature accuracy: ±1 °C ±0.5% of reading
Sensor maximum working pressure: 5,000 psig (344 barg)
Meter approvals, calibrations, and certifications: •UL•CSA•IECEx•NEPSI•ATEX•Ingress Protection•EMC effects
Output variables: Mass & volume flowNet product content / flowTemperatureDensityConcentration
Local display: Standard user interface with 2-line LCD panelTwo optical switches for local operationGlass or plastic lens options
Power: Self-switching AC/DC input, automatically recognizes supply voltage85 to 265 VAC, 50/60 Hz, 6 watts typical, 11 watts maximum18 to 100 VDC, 6 watts typical, 11 watts maximumComplies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) with amendment 2, and Installation (Overvoltage) Category II, Pollution Degree 2
Input/output signals: Not intrinsically safeAnalog output option:One active 4–20 mA outputOne active frequencty outputFrequency output can be configured as a discrete outputConfigurable I/O option:One or two active 4-20 mA outputsOne or two active/passive frequency outputsOne or two active/passive discrete outputsOne discrete inputIntrinsically safeAnalog output option:One passive 4-20 mA outputOne passive frequency outputFrequency output can be configured as a discrete outputFoundation™ fieldbus (Obsolete)optionally non-incendiveOne Foundation fieldbus H1 outputPROFIBUS-PA (Obsolete)One PROFIBUS-PA output
HART/WirelessHART: Bell 202 signal is superimposed on the primary milliamp outputWirelessHART available via THUM adapterHART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
Mounting options: Field-mountIntegrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensorRemotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types: Continuous process controlCustody transferTwo-phase flow/entrained gasMeter verificationSIS Certified
Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2
HART/WirelessHART: Bell 202 signal is superimposed on the primary milliamp outputWirelessHART available via THUM adapterHART communication is unavailable on Foundation fieldbus and PROFIBUS-PA transmitter versions
Mounting options: Field-mount•Integrally mounted to a Micro Motion F-Series, R-Series, or H-Series sensor•Remotely mounted to any 4-wire or 9-wire Micro Motion Coriolis sensor
Application types: Continuous process controlCustody transferTwo-phase flow/entrained gasMeter verificationSIS Certified
Hazardous approvals: Class I, Div. 1Class I, Div. 2Zone 1Zone 2