close
close

Rosemount

Micro Motion ELITE Coriolis Meter Consisting of CMF200H Sensor and 2400S Transmitter

Write a Review
SKU:
micro-motion-pkg-ft-cmf200h-2400s
Request a Quote
Mass flow accuracy (Liquid): ±0.10% of rate (standard)±0.05% of rate (optional) Mass flow repeatability (Liquid): ±0.05% of rate (standard)±0.025% of rate (optional) Volume flow accuracy (Liquid): ±0.10% of rate (standard)±0.05% of rate (optional) Volume flow repeatability (Liquid): ±0.05% of rate (standard)±0.025% of rate (optional) Mass flow accuracy (Gas): ±0.35% of rate Mass flow repeatability (Gas): ±0.20% of rate Density accuracy (Liquid): ±0.0005 g/cm3 (±0.5 kg/m3) (standard)±0.0002 g/cm3 (±0.2 kg/m3) (optional) Density repeatability (Liquid): ±0.0002 g/cm3 (±0.2 kg/m3) (standard)±0.0001 g/cm3 (±0.1 kg/m3) (optional) Temperature accuracy: ±1 °C ±0.5% of reading Sensor maximum working pressure: 2,755 psig (190 barg) Meter approvals, calibrations, and certifications: •UL•CSA•IECEx•NEPSI•ATEX•Ingress Protection•EMC effects Output variables: Mass & volume flowNet product content / flowTemperatureDensityConcentration Local display: Standard user interface with 2-line LCD panelTwo clips for HART/Bell 202 connections (requires removing transmitter housing cover)Two membrane pushbuttons for local operation (requires removing transmitter housing cover)Glass or plastic lens options Power: Self-switching AC/DC input, automatically recognizes supply voltage85–265 VAC, 50/60 Hz, 4 watts typical, 7 watts maximum18–100 VDC, 4 watts typical, 7 watts maximumComplies with low voltage directive 2006/95/EC per EN 61010-1 (IEC 61010-1) and Installation (Overvoltage) Category II, Pollution Degree 2 Input/output signals (analog output option): Channel A:One active 4–20 mA outputNot intrinsically safeChannel B (configurable), one of:One active or passive frequency outputOne active or passive discrete outputOne active or passive discrete input Input/output signals (PROFIBUS-DP option): Digital 2-way PROFIBUS-DP signal Input/output signals (DeviceNet option): Digital 2-way DeviceNet signal (Now Obsolete) HART: Bell 202 signal is superimposed on the primary milliamp outputHART communication is not available on PROFIBUS-DP and DeviceNet transmitter versions Mounting options: Field mount, integral with sensor Application types: Continuous process controlTwo-phase flow/entrained gasMeter verification Hazardous approvals: C1D2Zone 2
Worldwide Shipping
Tailored Quotation
Secure Shopping
24/7 Customer Support
Icon Hot
Icon Hot