The Flexim FLUXUS G722 ST-HT, the latest high-temperature model and is complementary to our existing FLUXUS ST-LT steam flow meters, but pushes clamp-on ultrasonic steam measurement up to 752 °F. This unique flow solution is based on the correlation flow measurement principle. The acoustic measuring method has exceptionally high measuring dynamics and functions independently of the flow direction. The FLUXUS G722 ST-HT offers precise bidirectional flow measurement over a wide turndown ratio up to 10:1. FLUXUS G722 ST-HT has no moving parts. Its ultrasonic transducers are fixed to the pipe with broad stainless steel straps or our patented high-temperature mounting system WaveInjector and secured in robust stainless steel housings.
Fluid type: Saturated and superheated steam
Accuracy: Measurement uncertainty at the measuring point (volumetric flow rate): ±3…4 % of reading
Repeatability: ± 1…3 % of reading
Flow Channels: 2
Range: Flow Velocity Range: depending on the application
Certifications/Approvals: FM Class I /Div 2ATEX/IECEx Zone 2PESOKOSHA
Power supply: 100-230VAC24VDC12VDC
Pipe size: 10 to 900 mm (0.39 to 35.4 inches)
Pressure range: 1 to 220 barg (15…3190 psig)
Temperature range (media): +100 to +630°C (+212 to +1166 °F)
Output: 4-20mA active/passive4-20mA HART active/passivepulse/frequency/binaryvoltage
Input: Temperature4-20mA active/passivebinaryvoltage
Communication Protocol: Modbus RTU/TCPBACnet MSTP/IPProfibus PAFoundation Fieldbus
System configuration and installation: For more detailed Information please download the Technical Specifications