The Flexim FLUXUS G721 ST-LT is a non-intrusive, high-performing ultrasonic clamp-on flow meter capable of measuring steam up to 356°F. With up to two measuring channels optimum recording is possible even with difficult flow condition. An optional stainless-steel housing and FM Class I Div. 2 certification allows usage in extreme conditions, and the flexible configuration options for signal inputs and outputs cover all manner of applications. For users, this means important advantages when considering the total cost of operating a measuring point. The transit time difference principle already works at 0.03 ft/s and does not need any reduction to the diameter of the pipe to artificially increase the flow velocity.
Fluid type: Saturated and superheated steam
Accuracy: Measurement uncertainty of the measuring system (volumetric flow rate): ±0.3 % of reading ±0,005 m/s (±0.02 ft/s)Measurement uncertainty at the measuring point (volumetric flow rate): ±1…3 % of reading ±0,005 m/s (±0.02 ft/s)
Repeatability: 0.15 % of reading ±0,005 m/s (±0.02 ft/s)
Flow Channels: up to 2
Range: Flow Velocity Range: depending on pipe diameter and transducer
Certifications/Approvals: FM Class I /Div 2ATEX/IECEx Zone 2PESOKOSHA
Power supply: 100-230VAC24VDC12VDC
Pipe size: 23 to 1000 mm (0.9 to 39.4 inch)
Pressure range: 3 to 10 barg (44…145 psig)
Temperature range (media): +135 to +180°C (+275 to +356°F)
Output: 4-20mA active/passive4-20mA HART active/passivepulse/frequency/binaryvoltage
Input: Temperature4-20mA active/passivebinaryvoltage
Communication Protocol: Modbus RTU/TCPBACnet MSTP/IPProfibus PAFoundation Fieldbus
System configuration and installation: For more detailed Information please download the Technical Specifications