The Flexim FLUXUS F70X SIL flow meter has always been the first choice when it comes to maintaining accurate measurements in harsh conditions – e.g. during the flow measurement of highly pressurised, aggressive, toxic or highly explosive liquid media. The SIL 2 certification of the F70X SIL non-invasive flow meter includes the entire measuring system - the measuring transmitters and transducers.
Certifications/Approvals: FLUXUS F70X: FM Class I, Div. 1, ATEX, IECEx Zone 1 approval, IP66, aluminium or stainless steel housing variants - suitable for offshore use
Measuring Quantities: volume flow rate, mass flow rate, flow velocity
Operating Temperature: Transmitter: 14 °F ... 140 °F
Certifications/Approvals: up to NEMA4X (IP68), radiation resistant transducers available
Temperature Range: Pipe Wall: -40°F ... 390°F (-275°F ... 1100 °F with high temperature WaveInjector mounting fixture)
Range: Flow Velocity Range: 0.03 ... 80 ft/sec
Pipe Size: 1/4 inch ... 500 inches
Uncertainty: Measurement uncertainty of the measuring system (volumetric flow rate): With standard calibration: ±1.6 % of reading ±0.01 m/sWith advanced calibration (optional): ±1.2 % of reading ±0.01 m/sWith field calibration: ±0.5 % of reading ±0.01 m/s
Accuracy: ± 0,5% of reading ± 0,01 m/s
Repeatability: ± 0.5% of reading ± 0.03 ft/s
Capacity: Data Logger: >100,000 values: all quantities, summed measurings and diagnostics
Communication Protocol: Modbus RTU
Power Supply: 100 to 240 V AC / 50 to 60 Hz or 20 to 32 V DC